Lightning gropes down blind, and the ground reaches up to meet it
A lightning flash does not leave the cloud aimed at anything. A faint channel of charge gropes its way down in short jumps, each one decided by the air right at its tip. Where it lands is settled in the last few dozen metres, when something on the ground sends a spark up to meet it. The bright flash you then see runs up, not down.
A channel that grows in jumps
Most flashes that reach the ground begin with a negatively charged channel called a stepped leader, which grows from the storm toward the ground. It does not grow smoothly. It lurches forward, pauses, and lurches again. Cruz and colleagues' 2025 study summarises measurements going back to the 1930s: steps from 3 to 200 metres long, with 0.2 to 100 microseconds between them.
A radio telescope has watched those steps from close up. Hare and colleagues used LOFAR, thousands of antennas spread across the northern Netherlands, to map the radio pulses from one 2017 flash, horizontally to within about a metre. Inside the cloud, the steps they saw were a median of 7.5 metres apart horizontally, with a median of 40 microseconds between them. Each step set off a burst of pulses at the leader's tip, which they read as a sudden spray of streamers: thin, faint sparks that run ahead into the air.
It cannot see the ground
Hare and colleagues describe the step like this. A new piece of channel suddenly takes on the leader's high voltage. The electric field just ahead of it jumps past the point where air breaks down, a bubble of ionised air swells out until the field at its edge falls back to that point, and the bubble breaks up into streamers. Somehow the streamers seed the next piece of channel; how, they wrote in 2020, was not understood. Most of the radio sources in each burst sat within about a metre of one another, at the tip.
So everything that steers the next step happens right at the tip. Nothing in it surveys the air far below, which means the leader cannot plan a route to the ground, let alone pick the easiest one. Its path comes out crooked, and it splits into branches that grope down side by side.
The leader is not slow, though. Cruz and colleagues filmed 107 stepped leaders in Utah at 40,000 frames a second. Their average speeds ranged from about 90 to 2,200 kilometres per second, and 91% of the leaders sped up in the last 500 metres, by 69% on average.
The ground reaches up
As the leader's charged tip comes down, the electric field at the tops of things below it grows stronger. Once the field at some spot is strong enough, a positively charged channel starts to grow upward from there to meet the leader. This is an upward leader. Tran and Rakov describe its start as the field at the would-be strike object reaching the threshold for launching a stable leader.
Tran and Rakov filmed the meeting at up to 210,000 frames a second in Gainesville, Florida, for four strokes that appear to have hit treetops 10 to 30 metres tall. The upward leader that made the connection grew 11 to 25 metres before it met the downward one. It was not the only one. In one stroke, seven other upward leaders rose from points 7 to 45 metres from the one that connected, and went nowhere. In another, an upward leader that never connected started before the one that did. Starting a spark, the authors note, does not by itself decide the strike point.
The end is fast. When the two leaders were roughly 30 to 40 metres apart, the faint zones of streamers ahead of their tips touched. Both ends then sped up to millions of metres per second and closed the gap in a few microseconds. Tran and Rakov call this the final jump.
Interactive The last 300 metres above the ground, seen side-on. Press Play to watch a stepped leader grope down, or Step to advance one step at a time. Change the tree's height, try New leader for a different path, or run 100 leaders and count what gets hit. Every control works with Tab, Enter and the arrow keys.
The flash runs upward
The leader has laid negative charge all along its path. Once the channel is joined, Rakov's 2007 review explains, a return stroke runs along that path from the ground toward the cloud and neutralises the charge. It is far brighter than the leader; in Tran and Rakov's films it often saturated the camera. Over the lowest few hundred metres it typically moves at a third to a half of the speed of light. Tran and Rakov also found that about half of the stroke's peak current was already flowing during the final jump, before the return stroke proper.
It usually happens more than once. Later leaders, called dart leaders, follow the channel already made, and usually appear to move smoothly rather than in steps. Each sets off another return stroke. Rakov's review gives three to five strokes for a typical flash to the ground. It also reports that about half of these flashes reach the ground at more than one point, sometimes kilometres apart. A flash can find the ground more than once.
In short
Lightning finds the ground by groping, not aiming. The stepped leader jumps metres to tens of metres at a time, steered only by the air at its tip. In its last few dozen metres, tall objects and the ground under it send up sparks of their own. Whichever one meets it first becomes the strike point, and the brightest part of the flash then runs back up the path the leader built.
Where this comes from
- Radio emission from negative lightning leader steps reveals inner meter-scale structure linked only, not reproduced
arxiv.org/abs/2007.03231 - Correlation between speed of the leader and peak current of the return stroke in negative lightning flashes (Geophysical Research Letters 52, e2024GL111594) linked only, not reproduced
doi.org/10.1029/2024GL111594 - A study of the ground-attachment process in natural lightning with emphasis on its breakthrough phase (Scientific Reports 7, 15761) linked only, not reproduced
doi.org/10.1038/s41598-017-14842-7 - Lightning phenomenology and parameters important for lightning protection (IX International Symposium on Lightning Protection, Foz do Iguaçu, Brazil) linked only, not reproduced
www.eskom.co.za/wp-content/uploads/2026/10/75.-rakov-2007.pdf